Technical Parameters
Parameter of safety light curtain | |
Supply voltage | DC24V±15% |
Beam space | 20mm, 40mm |
Resolution | 25mm, 45mm |
Beams | 20mm beam space: 32, 6440mm beam space: 16, 32 |
Wave length | 940nm |
Capacity | <5W |
Sensing distance | Max 20m (Remark: if light reflection, please let us know in advanced) |
Anti-optical interference | 10000Lux (Incidence Angle I >5) |
Sensing method | Through-beam type |
Output mode | NPN, PNP, RS485 |
Type of output(OSSD) | PNP/NPN semiconductors,current <200mA max, residual voltage: 1V max. leakage current: 1mA. (Expect voltage influenced by lengthen wire).RS485 output: Modbus communication protocol, customized protocol. |
Protective circuit | Power supply over voltage protection, reverse polarity protection and output over current protection. |
Output signal | OSSD 1 output blocking signal, OSSD 2 output abnormal signal |
The Emission Indicator | Normal: The indicator is steady green |
The Receiving Indicator | Normal: The green light is steady onAbnormal alignment: The indicator is steady redCP malfunction: Red & green light blink alternately. |
Insulation Resistance | >100MΩ |
Ambient Operating Temperature | -40ºC-55ºC |
Storage Temperature | -55ºC-80ºC |
Ambient Humidity | When the temperature is 20 ºC, the relative air humidity is less than 85% |
Enclosure rating | IP65 |
Housing cross-section | 35*50mm |
Electrical parameters of the protective cover | |
Operating Voltage | 24V±10% |
Working Current | 10A |
Humidity Switch | Mechanical nylon film trigger switch relative temperature 20%-80% |
Main Control Unit | When the heating unit of the starts, the red LED light at the front will grow |
Cover Structure | Stainless Steel (201/304) |
Cover | Self-adjusting heating glass |
Heating Glass | Core 2 No. 14 standard cable will ground cable is required for heating glass (cable not provided) |
Door Opening Method | Front-door opening mode |
Door Closing Method | Front-door screws fixed |
Wire Connection
Explanation of Model Number
Beam space 20mm