Technical Parameters
| Parameter of safety control module | |
| Electrical data | |
| Power supply | 20V~30VDC |
| Electricity break | ≤110mA(24VDC) |
| Input feature | |
| Channel | 6 |
| Input current | ≤50mA(24VDC) |
| Wire resistance | ≤15Ω |
| Support device | Emergency stop, safetygate, safety light curtain, safeyt mat, two hand button, interlock switch, reset button |
| Output feature | |
| Contacts | 2NO |
| Material of contacts | AgSnO₂ |
| Fuse protection | 10A fast;6A slow |
| Switching capacity | 5A/250V AC; 5A/24V DC |
| Semiconductor feature | |
| Output | 4PNP |
| Drive power | 2A(24V DC) |
| Time feature | |
| Operation time | ≤100ms |
| Release time | ≤30ms |
| Restore time | ≤100ms |
| Power break time | 20ms |
| Ambient feature | |
| Electro magnetic compatibility | EN60947,EN61000-6-2,EN61000-6-4 |
| Vibration | Frequency:10Hz~55Hz;Amplitude:0.35mm |
| Ambient temperature | -20℃~+60℃ |
| Storage temperature | -40℃~+85℃ |
| Relative Humidity | 10%~90% |
| Insulating feature | |
| Overvoltage level | Ⅲ |
| Pollution level | 2 |
| Rated insulating voltage | 250V AC |
| Rated impact voltage | 6000V (1.2/50us) |
| Dielectric strength | 1500V AC,1min |
| Clearance & creepage | EN60947-1 |
| Certificates | |
| Safety level | SIL 3 |
| Safety level (SIL/PL) | PL e |
| Safety category | Cat.4 |
Product Size

Panel function

Connection diagram
| 4 channel emergency button input |
![]() |
| 2 channel two-hand button input |
![]() |